Max10: ADC no longer working which have .pof document

Max10: ADC no longer working which have .pof document

Sorry, you need to ensure to-do this step. Excite click the confirmation connect on the current email address. You may also lso are-publish during your reputation.

  • Intel Area
  • Tool Service Forums
  • FPGA
  • Automated Equipment
  • Max10: ADC no longer working that have .pof document
  • Mark Question because the New
  • Mark Procedure just like the Realize
  • Float this topic getting Most recent Representative

I believe you have got one (or more) some sluggish or less than ranked supplies

I’m currently dealing with Max10M16DAF256 and i also struggle with this new ADC. sof file it works fine. pof file new ADC does not work more, i.elizabeth ADC information is usually zero, as anybody else elements really works truthfully.

While using

I have in addition to viewed that whenever coding which have .pof file but still allow suppy voltage into, new ADC really works. But after reset the supply voltage (turn fully off and on again), it will not functions thaiflirting -app more.

In the event the second you will need to confirm look at the way you release the new ADC Ip off reset. Hold on a minute into the reset ‘a little longer’ following increase. Disappointed this may sound a little obscure. That it appears to be a frequent topic with the message board you to does not appear to have acquired a very clear, legitimate provider.

If this sounds like your own board you will need to check on the above mentioned and ensure the latest rails rise monotonically. There are no sequencing conditions if the usually do not increase correctly – maybe not appointment the fresh Tramp date – the computer often misbehave. Refer to ‘Figure 3. Tracked Electricity Offers Ramp Up’ in the ‘ fuel administration affiliate guide (

I also found a comparable problem with Max10 ADC an additional bond, however, as if you told you there is no service for it.

The board is actually all of our notice framework panel. The issue is that many of the chatrooms work good which have ” .pof “-document, and some of them fully grasp this ADC situation. On chatrooms that have ADC problem, i examined throughout the hardware of these chat rooms regrettably we missed any problem on the hardware. Including listed above, this new chatrooms will work which have ” .sof ” and also ” .pof “-file if also provide voltage is into the. Pursuing the likewise have voltage try reset, the latest ADC does no longer performs because others continues to be operating correctly.

This makes myself faith a whole lot more this issue is energy related. You happen to be certainly with the side of whatever the concern is provided you have got performing chat rooms.

Might you take a non functioning panel, disconnect the benefit offers and you can energy it regarding bench provides? My concern is that a not as much as ranked rail isn’t around giving the inrush required and dips evoking the POR circuitry good situation, and this (perhaps) isn’t really noted.

You are proper. I did specific study on the stamina offers to have Max10, also it seems like the analog also have requires some a lot of time up to it has reached complete current level (the audience is playing with Max10 twin also provide product, hence need one or two electronic provides and you can step 1 analog supply).

As in Max10 Energy government member publication, it looks like just the past power having Max10 count (attached picture), therefore we tried to swtich on the analogue also provide first and you may watch for it to arrive maximum level, after which turn on additional a few electronic supplies, hence get only couples hundred µs to reach maximum height. This will help the newest maybe not-working ADC becoming doing work sporatically (not at all times functioning).

But when we get an operating panel (ADC always performs) and you may perform the opposite succession (i.e assist several electronic offers on first, then analog supply), this new ADC has been working (i expected so it shouldn’t work anymore).

Therefore somehow this new ADC disease refers to the power also have series therefore the ramp time of energy offers, however, a definite cause because of it situation might have been not found yet ,.